          | Serial number | Equipment Name | quantity | unit | Remark | 
| 1 | Vertical tr*ning platform | 1 | tower | |
| 2 | Mesh plate installation module | 8 | piece | |
| 3 | Expansion fixings for mesh panels | 100 | indivual | |
| 4 | Cable Management | 12 | indivual | |
| 5 | Power Management Module | 1 | tower | |
| 6 | Embedded programming host and display module | 1 | set | |
| 7 | Fire alarm controller (linkage type) | 1 | tower | |
| 8 | Electronic encoder | 1 | indivual | |
| 9 | CRT Interface Card | 1 | piece | |
| 10 | Fire Alarm Monitoring Software | 1 | set | |
| 11 | Communication Cable | 1 | strip | |
| 12 | Phone Host | 1 | tower | |
| 13 | Broadcast Power Amplifier | 1 | tower | |
| 14 | Distribution plate | 1 | tower | |
| 15 | Bus Isolator | 3 | indivual | |
| 16 | Fire display panel | 1 | indivual | |
| 17 | Non-encoded detector input module | 1 | indivual | |
| 18 | Non-coded point type heat detector | 2 | indivual | |
| 19 | Terminal | 1 | indivual | |
| 20 | Point-type photoelectric smoke detector | 1 | indivual | |
| twenty one | manual alarm button | 1 | indivual | |
| twenty two | Fire hydrant button | 1 | indivual | |
| twenty three | Input/output modules | 3 | indivual | |
| twenty four | Smoke exhaust valve simulation (relay) | 1 | indivual | |
| 25 | Sound and light alarm | 1 | indivual | |
| 26 | Fire telephone dedicated module | 1 | indivual | |
| 27 | Fire telephone socket | 1 | indivual | |
| 28 | Fixed fire telephone extension | 1 | indivual | |
| 29 | Portable fire telephone extension | 1 | indivual | |
| 30 | Fire broadcast module | 1 | indivual | |
| 31 | Wall-mounted emergency broadcast speaker | 1 | indivual | |
| 32 | Switching Modules | 6 | indivual | |
| 33 | Smoke exhaust fan simulation | 1 | indivual | Fan | 
| 34 | Smoke exhaust fan contactor simulation | 1 | indivual | Relay | 
| 35 | Signal input module | 1 | indivual | |
| 36 | 270℃ Fire damper simulation | 1 | indivual | Relay | 
| 37 | Fire pump control box simulation | 1 | indivual | Indicator lights, relays, switches | 
| 38 | Fire pump simulation | 2 | indivual | Fan | 
| 39 | 6-bit PD power supply | 1 | indivual | |
| 40 | 24-position Category 5e non-shielded socket patch panel | 1 | indivual | |
| 41 | 8P8C Category 5e non-shielded crystal head | 20 | indivual | |
| 42 | Category 5e non-shielded information socket module | 4 | indivual | |
| 43 | Single port 86 type information panel | 4 | indivual | |
| 44 | 86 type bottom box | 4 | indivual | |
| 45 | TP Category 5e 4 p*rs of unshielded patch cord | 4 | strip | |
| 46 | TP Category 5e 4-p*r unshielded cable | 100 | rice | |
| 47 | Special bridge | 1 | set | |
| 48 | Consumables and tools | 1 | set | Wires of various specifications, common electrical tools and cable testers, etc. | 