          | serial number | Fault simulation instructions | Fault phenomenon | 
| K1 | Refrigerator power supply detection connection | The computer board does not have power and the whole machine does not work | 
| K2 | External fan circuit detection connection | The computer board does not have power and the whole machine does not work | 
| K3 | Air conditioning, compressor detection connection | The computer board does not have power and the whole machine does not work | 
| K4 | Four-way valve detection connection | There is no +5V DC power output, and the whole machine does not work | 
| K5 | Indoor fan high wind detection connection | |
| K6 | Indoor fan stroke detection connection | |
| K7 | Indoor fan low wind detection connection | |
| K8 | Indoor pipe temperature sensor short circuit | |
| K9 | f1 start capacitor open circuit | The motor cannot start and does not work | 
| K10 | f1 running winding open circuit | The motor cannot start and does not work | 
| K11 | Four-way valve YV coil open circuit | The four-way valve does not work and does not work in heating conditions | 
| K12 | Protection relay SAT open circuit | The compressor does not work | 
| K13 | Indoor temperature sensor short circuit | The compressor cannot work and the starting current is very high | 
| K14 | Compressor running winding CM open circuit | The compressor cannot work and the starting current is very high | 
| K15 | Quick Freeze Circuit Detection Connections | |
| K16 | Relay RLY5 coil working test | When simulating indoor speed regulation, high-speed wind speed does not work | 
| K17 | Relay RLY4 coil working test | When simulating indoor speed control, the mid-range wind speed does not work | 
| K18 | Relay RLY3 coil working test | When simulating indoor speed regulation, the lowest wind speed does not work | 
| K19 | Relay RLY2 coil open circuit | Four-way valve body does not move | 
| K20 | Relay RLY1 coil operation detection | The compressor is not working | 